Sanyo Denki servo amplifiers run in machine tools, semiconductor equipment and packaging lines for decades, and the two generations most technicians meet are the older PY series and the current SANMOTION R series. They report faults differently: a PY amplifier flashes a letter-style code on its 7-segment display (OC, OL, OV, DE...), while an R amplifier shows a two-digit numeric code (21, 41, 61, 85...) and outputs it on the ALM1–ALM8 bits of CN1. Codes are also logged in the alarm trace mode of the Remote Operator and the setup software — the first place to look on a machine that faults once a shift. This guide lists both series' verified alarm codes and the repairs that return the axis to service, cross-checked against the PY manual (Table 21), the SANMOTION R Instruction Manual alarm list and the R CANopen interface manual.
Sanyo Denki kept the same fault taxonomy across generations but renumbered it. The R manual publishes a "PY compatible code" column; four mappings cover the alarms you will hit most: R 21 (overcurrent) = PY 1 (OC), power module overcurrent; R 61 (overvoltage) = PY 5 (OV), DC bus overvoltage; R 43 (regenerative error) = PY J (RGOL), regeneration fault; R 85 (encoder initial process error) ≈ PY 8 (DE), encoder did not initialize. When an older machine is retrofitted with an R amplifier, expect the same problem under a different number, and remap any PLC logic watching the old PY alarm outputs.
The PY display flashes the code; the same code sets output pins CN1-43/44/45/46 and appears in alarm trace mode.
| Display | Abbr. | Meaning |
|---|---|---|
| 1 | OC | Overcurrent |
| 2 | OL | Overload |
| 3 | AOH | Amplifier overheating |
| 5 | OV | Overvoltage |
| 6 | OS | Overspeed |
| 7 | PE | Control power supply error |
| 8 | DE | Detector error – encoder |
| 9 | MPE | Bus power (R/S/T) error |
| A | FP | Bus power phase missing |
| C | SE | Speed control error |
| D | OVF | Position deviation overflow |
| E | EXOH | External regeneration resistor overheating |
| F | DSPE | DSP error |
| H | RGOH | Internal regeneration resistor overheating |
| J | RGOL | Regeneration error |
| P | MEME | Memory error |
| U | AEE | Absolute encoder battery alarm |
| blank | CPUE | CPU error |
OC (1): overcurrent in the power stage. Root causes: a shorted motor cable, phase-to-phase or phase-to-ground winding failure (often cutting-fluid ingress — windings read fine cold but trip at speed), or a failed power transistor. Repair: megger the motor and cable disconnected from the amplifier; if the motor is clean, the power stage is suspect and goes out for board-level repair. Never run a withstand-voltage test on the motor or drive yourself — it destroys them.
OL (2): the effective torque exceeded the rating for the duty cycle. Check for a brake that is not releasing (measure brake voltage at the connector), a binding mechanism, incorrect motor–amplifier pairing, or UVW wiring swapped after a motor change. If mechanics are sound, raise the acceleration time and re-check the inertia ratio.
Deceleration energy charges the DC bus and the regeneration resistor burns it off, so four codes describe one system. OV (5): bus voltage over limit — decel too fast for the resistor capacity, line spikes, or a disconnected/wrongly sized resistor. RGOH (H): internal resistor overheating — duty just beyond its capacity. RGOL (J): regeneration fault — resistor disconnection, wrong external resistance, or excessive inertia with short decel times. EXOH (E): external resistor overheating — undersized or poorly ventilated. Repair: measure the external resistor against the specification, verify the selection parameter matches the hardware, soften deceleration profiles and add airflow.
- DE (8): encoder signal fault. Reseat the encoder connector at both ends, check the cable for drag-chain damage and shielding to ground, and try a known-good cable. Persistent DE with a good cable points to the encoder itself. - MPE (9) / FP (A): bus power trouble — voltage out of range or a missing phase in R/S/T. Check input fuses, contactor poles and terminal tightness; a loose lug gives intermittent phase-loss alarms under load. - PE (7): control power supply error — usually internal; check the 24 V control feed first. - OVF (D): position deviation overflow — mechanical stall, loss of encoder counts, or position gain too low for the move profile. - SE (6 OS) / SE (C): overspeed and speed control error — wrong speed feedback wiring or an unstable speed loop after a parameter change; restore defaults and retune. - AOH (3): amplifier overheating — clean heat sink and fans, verify ambient temperature.
SANMOTION R numeric codes group by decade:
- 21–24 — current system: power module overcurrent and current detection errors. - 41–45 — load: overload 1/2, regenerative overload, average continuous overspeed. - 51–56 — heat: amplifier temperature, in-rush resistor, dynamic brake resistor, internal/external regeneration resistor, drive module overheat. - 61–63 — main circuit: overvoltage, main circuit undervoltage, main power phase failure. - 71–73 — control power: control circuit undervoltage 1/2, ±12 V undervoltage. - 81–87 — encoder signals: pulse error, absolute signal disconnect, external encoder pulse error, communication error, initial process error, CS signal disconnection. - A1–B7 — encoder internals: including A2 battery error, A3 encoder overheat, B3/B4 counter errors, B6 memory error. - C1–C3 — speed: overspeed, speed control error, speed feedback error. - D1–D3 — position: excessive following error, position command pulse frequency errors. - E1–F2 — processor/system: EEPROM error and checksum, internal RAM, CPU–ASIC process error, parameter errors 1/2, task process error, initial process timeout.
The stop behavior differs by family: DB stops the axis in dynamic brake, SB in a controlled stop with current limiting — a DB-stopped vertical axis will drop unless the brake holds it.
21 (overcurrent): same physics as PY OC — UVW short or ground fault, or a failed drive module. Disconnect the motor, megger it, and check the cooling fan; an overheated module can trip before any real short exists.
43 (regenerative overload): the resistor duty exceeded its rating. If no external resistor is fitted and the axis decelerates a large inertia, add one and set the resistor selection parameter correctly (sy-0B = 01 for an external resistor).
61 / 62 / 63: 61 mirrors PY OV — line spikes or regeneration; 62 means the bus sagged below spec — check incoming supply and soft-start; 63 is a missing input phase — fuses and contactor poles first.
85 (encoder initial process error): the amplifier failed to initialize the encoder at power-up — usually a disconnected or damaged cable. Reseat connectors and swap the cable before ordering an encoder.
A2 (absolute encoder battery error): replace the battery with control power ON and the machine in a safe state, then re-home the axis.
E2 (EEPROM checksum): parameters corrupt — typically a power interruption during a parameter write from the setup software. Attempt a standard-parameter rewrite; if the alarm returns on every power-up, the unit needs repair.
1. Record the display code and alarm trace history before touching anything. 2. Power down, lock out, and wait for the bus capacitors to discharge. 3. Separate amplifier from motor: megger the motor and cable; inspect connectors for contamination. 4. Check the mechanical chain: brake release voltage, coupling, belt, load binding. 5. Verify the power side: three-phase voltages, fuses, DC bus level, regen resistor resistance. 6. Power up and watch which family re-registers — current alarms with a clean motor point to the amplifier; load alarms point to sizing or tuning. 7. Restore defaults and retune if the fault appeared after a parameter edit.
For amplifiers confirmed faulty, board-level repair is a specialist job — but spares strategy is not: a tested drive and motor on the shelf converts a weeks-long repair into an hour's swap. We also stock tested Yaskawa servo equipment: the SGDV-1R6A11A Σ-V servo drive, the SGDH-01AE-OY Σ-II amplifier, the SGMAV-C2A3A61 servo motor and a broad servo drive and motor collection.
- Resistors: annually measure regen resistor values; drift beyond ±10% predicts the first 43/RGOL alarm. - Batteries: replace absolute encoder batteries every 3–4 years, logged per axis. - Cables: inspect encoder and motor cables in drag chains yearly; most 8x/DE/81-series alarms are cable fatigue, not encoder death. - Cooling: clean heat sinks and fans every 6 months; overheat alarms track dust, not hours. - Parameters: back up parameters after every tuning session — an E2 error without a backup means re-tuning from scratch.
Q: My PY shows a flashing number but no letter — which table applies? A: PY codes are single characters (1–9, A, C–F, H, J, P, U). A two-digit number like 41 belongs to an R-series amplifier.
Q: Can I clear a PY alarm by power cycling? A: OC, OV and overheat codes reset once the cause is gone, but repeated cycling without fixing the cause damages the power stage. Read the alarm trace history instead.
Q: Is the R-series 85 alarm always a broken encoder? A: No — a damaged cable or loose connector causes most 85 alarms. Swap the cable first.
Please check our servo drive collection for tested servo amplifiers, drives and motors from Sanyo Denki's peer brands.